PM23460: Creating project from baseline fails in 7.1.1.3

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In RQ baseline manager on Windows 7 Creating a project from
    baseline fails with error:'error in Frmwizard.CreateAndOpenRQS
    file(-2147219364): error loading queries' - see attached
    image1.png.
    
    This failure happen even if baseline has been created locally on
    the same RQ version.
    
    The issue doesn't happen in previous 7.1.1 version
    
    Steps to reproduce:
    
    deploy a win7  image
    install Rqpro 7.1.1
    Test base line create and restore i.e.: use samples
    upgrade to 7.1.1.03
    retest baseline creation and restore
    when restoring you will have the error
    
    issue must be RQ Baseline manager related because it worked on
    older versions and newest on same system parameters is failling.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Create a project from baseline using RequisitePro Baseline
    Manager fails if the target database is Access. An error
    message is shown:
    Error in frmWizard.CreateAndOpenRQSFile (-2147219364 ) :
    Error loading parameter queries.
    
    RequisitePro Baseline Manager was flushing parameter queries
    before time to save memory.
    

Problem conclusion

  • RequisitePro Baseline Manager has been modified to preserve
    the parameter queries it needs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM23460

  • Reported component name

    REQUISITEPRO WI

  • Reported component ID

    5724G3900

  • Reported release

    711

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-29

  • Closed date

    2014-03-19

  • Last modified date

    2014-03-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    REQUISITEPRO WI

  • Fixed component ID

    5724G3900

Applicable component levels

  • R711 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHCT","label":"Rational RequisitePro"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: