IBM Support

PM21991: layout column which checks default view then opens baseline causes crash

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem
    If you create a view which contains layout code which first
    checks the default view for the module, then opens a baseline,
    DOORS will crash when loading the view.
    
    The message given when the crash ocurrs appears to vary
    according to platform and/or DOORS version.
    
    To Reproduce
     - create a baseline v0.1 in a module
     - add a layout column containing the following code and save it
    in a public view:
    
    '
    Module m = current
    
    getDefaultViewForModule(m)
    load (baseline (0, 1, ''), true)
    '
    
     - reopen the module and load the view
    
    Possible Workarounds
    In some cases, simply creating a new view, after the problem
    one, will allow it to load correctly.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If you create a view which contains layout code which first
    checks the default view for the module, then opens a
    baseline, DOORS will crash when loading the view.
    

Problem conclusion

  • The code has been changed so that a crash does not occur in
    this scenario
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM21991

  • Reported component name

    TLOGIC DOORS AN

  • Reported component ID

    5724V85DA

  • Reported release

    430

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-06

  • Closed date

    2011-03-31

  • Last modified date

    2011-03-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS AN

  • Fixed component ID

    5724V85DA

Applicable component levels

  • R430 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQDN","label":"Rational DOORS Analyst Add On"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: