  • Environment:
    - Windows XP
     - Rational Bussiness Developer v 7.5.1.5
    Reproducible Y/N: NA
    Description of problem:
    This goal of this documentation defect is to cover following 2
    points mentioned below.
    
    Regarding the preventDefault function,  the function from the
    Event.js file is not being used.  An event does support the
    preventDefault function, and it will either run the function
    that is provided by the browser, or a function provided by the
    EGL Runtime if the browser event does not support
    preventDefault.  This detail needs to be clarified in the
    documentation.
    
    As noted, an event will bubble up from the widget that fired the
    event until it is processed by an EGL function.  Once the EGL
    function processes the event, the event will no longer be passed
    to any parent widgets.  This detail needs to be clarified in the
    documentation.
    
    Step to reproduce:
    Workaround:
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The help topic "Event handling in Rich UI" is updated for
    the next release of EGL
    

Problem conclusion

  • The topic "Event handling in Rich UI" is updated in the
    version 8.0.1 documentation
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM21494

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-30

  • Closed date

    2010-12-07

  • Last modified date

    2010-12-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R751 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]