Error description
TD# 34679 DOORS 9.2, QC 10, QCI 3.4.0.1 Create a module in DOORS with two objects Create a Task to sync this module to QC and then execute the sync You notice in QC, under the Requirements tab it creates a parent object for the module then beneath that creates two child objects representing the two objects from the module Now, re-open the DOORS module and move object 1 to be after object 2 Re-sync the QCI task It look as if the sync completes, but if you look at the sync summary you notice: ?ObjectError? Move failed for TD id:TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:7 to (same) parent TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:5 Move failed for TD id:TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:6 to (same) parent TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:5?/Objec tError? And if you now do a refresh in QC, you will notice that for some reason those 2 module objects are now at the root level of the Requirements tab and no longer a child object of the parent module object. Workaround is to do a subsequent sync and the requirements are restored in proper order.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** When executing a synch task which has requirements that have been moved around in the DOORS module, the synch throws an error and the requirements are re-arranged in QC.
Problem conclusion
The code has been changed so that the synch no longer throws an error and also the requirements are not re-arranged.
Temporary fix
Comments
APAR Information
APAR number
PM21244
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-08-25
Closed date
2010-12-08
Last modified date
2010-12-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R920 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
01 May 2020