PM21244: QCI 3.4.01 sync errors when requirements are moved around

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • TD# 34679
    
    DOORS 9.2, QC 10, QCI 3.4.0.1
    
    Create a module in DOORS with two objects
    Create a Task to sync this module to QC and then execute the
    sync
    You notice in QC, under the Requirements tab it creates a parent
    object for the module then beneath that creates two child
    objects representing the two objects from the module
    Now, re-open the DOORS module and move object 1 to be after
    object 2
    Re-sync the QCI task
    It look as if the sync completes, but if you look at the sync
    summary you notice:
          ?ObjectError?
    Move failed for TD
    id:TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:7 to
    (same) parent
    TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:5
    Move failed for TD
    id:TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:6 to
    (same) parent
    TD:http\://usir-citrxsup\:8081/qcbin/:DEFAULT:new10:REQ:5?/Objec
    tError?
    
    And if you now do a refresh in QC, you will notice that for some
    reason those 2 module objects are now at the root level of the
    Requirements tab and no longer a child object of the parent
    module object.
    
    Workaround is to do a subsequent sync and the requirements are
    restored in proper order.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When executing a synch task which has requirements that have
    been moved around in the DOORS module, the synch throws an
    error and the requirements are re-arranged in QC.
    

Problem conclusion

  • The code has been changed so that the synch no longer throws
    an error and also the requirements are not re-arranged.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM21244

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-25

  • Closed date

    2010-12-08

  • Last modified date

    2010-12-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
01 May 2020