  • Closed as program error.

Error description

  • User is running RBD 7.5.1.5 on Windows and is trying to generate
    a Cobol program. The generation is successful, but the PREP
    step, which uses Distributed Build, fails.
    In the Environment, the default Java compiler is at a lower
    
    version
    than is required by Distributed Build.  It is expected that
    Distributed Build would fail in this case, but  the user is
    presented with a confusing message.
    
    
    
    When  the user submits a generate for  a Cobol program on RBD, a
    message is issued that
    the build failed, and the results are in a Build Results file in
    the generation directory.
    
    When  the user submits a generate for  a Cobol program, with
    PREP=YES, on RBD
       1. The generation fails very quickly (in a few seconds)
       2. The following message is issued:
           IWN.VAL.9995.e 0/0 The build for <program_name> failed.
    Refer to the results file
    <genout_Directory>\<program_name>_cbl_Results.xml for details.
      3. The genout directory does not contain the mentioned results
    file.
    
    The real error is that when Java was used to launch the
    buildplan, it failed with an exception which
    indicated the version mismatch. However, this information is not
    used and a generic, and incorrect message is issued.
    
    The code should look at the real exception and issue a more
    appropriate message.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The error message is wrong, when an unusual exception occurs
    during the execution of the build plan. The error message
    states to view the result.xml file, but sometimes it is
    possible to have an error before the xml file has been
    created. This made it difficult to determine the problem.
    

Problem conclusion

  • Now an additional message is displayed that gives the
    excdeptoin error message's text, to aid in determining the
    error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM21128

  • Reported component name

    RBD EGL FOR COB

  • Reported component ID

    5724S5001

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-24

  • Closed date

    2011-05-06

  • Last modified date

    2011-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RBD EGL FOR COB

  • Fixed component ID

    5724S5001

Applicable component levels

  • R751 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
06 May 2011