Error description

  • When enabling work area maintenance for a large hierarchy with m
    ultiple subprojects, many of the subproject work areas are writt
    en to the top-level absolute location.  These are not written to
     their correct relative location, and some are not written at al
    l.
    
    Analysis reveals that this occurs when the hierarchy contains on
    e or more sets of subprojects that share the same name, but diff
    er in version and/or instance AND the 'Include project-specific
    directory in work area path' option is NOT selected.  Messages i
    n the message view look like this:
    
            Setting path for work area of '?4-part project name?' to
     'C:/MyDir'...
            The work area for '?4-part project name?' will be mainta
    ined automatically.
            Synchronizing ...
            Warning: Work area path is not for this project, indicat
    es obsolete work area for project
            Serious: Errors occurred during synchronization
            Synchronization summary:
             0 Update(s) for project ?4-part project name?
             0 Conflict(s) for project ?4-part project name?
            Warning: Errors occurred during synchronization. Check y
    our logs.
            Saved work area options for project: '?4-part project na
    me?'
    
    One workaround is to ensure that the 'Include project-specific d
    irectory in work area path' option is selected.
    
    This is a regression from the way that traditional mode performs
    . Using traditional mode the hierarchy gets written correctly an
    d is thus another workaround.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Failure to write certain subprojects when a relative
    hierarchy contains subprojects with the same name, the
    project specific directory is set to false and work area
    path is not defined
    

Problem conclusion

  • This has been fixed in Synergy iFix 7.1.0.2.01.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM18845

  • Reported component name

    TLOGIC SYNERGY

  • Reported component ID

    5724V66SN

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-20

  • Closed date

    2010-12-22

  • Last modified date

    2010-12-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC SYNERGY

  • Fixed component ID

    5724V66SN

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSC6Q5","label":"Rational Synergy"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
22 December 2010