APAR status
Closed as program error.
Error description
Users are seeing the following error when creating a document in the project: 'Unable to add item to the package. Reason: The current user does not have sufficient package permis sions to move the requested element from the current package.' Once the error appears and the project explorer is refreshed the document shows up in the root package. STEPS TO REPRODUCE: 1. Create a project. 2. Edit user permissions and remove delete permissions. 3. Edit package security and remove delete permissions for docum ents. 4. Open a package and create a document.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Due to the original design of how Rational RequisitePro client for Windows creates documents, it first creates the document into root and then moves it out to the target package. So the document, once created in root, should be deleted and then added to the target package. But if the user does not have privilegies on root package to delete documents, the application complains and an error prompts stating the user does not have privilegies to delete the document. This is a problem since the user action does not mean to move any item, user wants to just create a document. The background process should be transparent to the user.
Problem conclusion
The document is created into the target package so there is no need to create it into root and then moved it out to the target package.
Temporary fix
Comments
APAR Information
APAR number
PM13228
Reported component name
REQUISITEPRO WI
Reported component ID
5724G3900
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-27
Closed date
2010-08-19
Last modified date
2010-08-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
REQUISITEPRO WI
Fixed component ID
5724G3900
Applicable component levels
R700 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHCT","label":"Rational RequisitePro"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
19 August 2010