APAR status
Closed as program error.
Error description
Rhapsody gives the several errors stating that certain oxf calls are ambiguous.These errors are seen when you have a reactive cl ass inheriting from another reactive class and an interface.The base reactive class does not virtually inherit from OMReactive class and hence the errors on ambiguous calls. See attached model and video file.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Compilation error due to double inheritance of OMReactive.
Problem conclusion
You can now use the new property, CPP_CG::Framework::ReactiveBaseAsVirtual, to set the base reactive class to virtually derive from OMReactive.
Temporary fix
Comments
APAR Information
APAR number
PM11064
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-29
Closed date
2011-01-11
Last modified date
2011-01-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R751 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]