Error description

  • When a WebSphere MQ Link receiver is active, it receives
    batches of messages from a queue manager and sends them to
    destinations in the Service Integration Bus.  After each batch,
    the WebSphere MQ link receiver must commit the messages and
    acknowledge them to the queue manager.  In rare cases, the
    WebSphere MQ Link receiver may shut down after successfully
    acknowledging a batch of messages.
      In the WebSphere Application Server SystemOut.log file there
    is no indication of an error, just message CWSIC3232I
    ("WebSphere MQ link ■X ended normally.")  The error logs on the
    queue manager will show more serious messages like AMQ9206
    ("Error sending data to host ■X", possibly including a TCP/IP
    error code like EPIPE) and AMQ9999 ("Channel program ended
    abnormally").
      This problem does not affect WebSphere MQ Links in
    WebSphere Application Server V7.0.
    

Local fix

  • If the WebSphere MQ sender channel is configured to retry, it
    should restart successfully and continue sending messages.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of the default messaging provider     *
    *                  for IBM WebSphere Application Server v6.1   *
    ****************************************************************
    * PROBLEM DESCRIPTION: WebSphere MQ Link Receiver shuts down   *
    *                      after successfully sending a            *
    *                      batch of messages.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The MQ Link way shut down after it has successfully
    acknowledged a batch of messages. This was due to a timing
    issue where the state of the receiver was examined at the same
    time that new work arrived. No error message is seen in the
    log and the MQ Link is seen to shutdown normally.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PM09797

  • Reported component name

    PLAT MSG COM

  • Reported component ID

    620600101

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-03-11

  • Closed date

    2010-03-22

  • Last modified date

    2010-03-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PLAT MSG COM

  • Fixed component ID

    620600101

Applicable component levels

  • R200 PSY

       UP