IBM Support

PM08057: Right clicking on a table sends a excessive number of requests to DB2 causing Data Source Explorer slow response

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When you click on the '+' sign next to a table in Data Source
    Explorer, it takes a long time to respond.  Depending on how
    many rows are in the table selected, the response can take
    anywhere from 3 seconds to 5
    minutes.  The more columns there are in a table, the longer the
    response time.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    There is a method called 'loadColumns' for DB2 ZSeries
    database. Another method is invoked inside this method for
    retrving the values of the field 'FLDPROC' of the system
    table SYSFIELDS. The fix is stopping the call of this method
    if the table is empty by putting a condition. This condition
    will call this method only when the SYSFIELDS table is
    filled, otherwise won't call the method unnecessarily. This
    query to search the FLDPROC values from SYSFIELDS table
    takes more time. So to avoid firing this query when not
    required will save a lot of time and response for loading
    columns will be faster.
    

Problem conclusion

  • The fix is available in Rational Application Developer
    v7.5.5.2.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM08057

  • Reported component name

    RATL APP DEV WI

  • Reported component ID

    5724J1901

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-02-19

  • Closed date

    2010-10-08

  • Last modified date

    2010-10-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL APP DEV WI

  • Fixed component ID

    5724J1901

Applicable component levels

  • R750 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information