Error description
Customer is experiencing the following problem: 'Runtime error - Object variable or with block variable not set' when editing a document via ReqWeb and tagging a new requiremen t. This error is thrown, if the user attempts to tag a requirement by either clicking on the Create Requirement button, going to Re quisiteWeb ? Requirement ? New Mark, or RequisiteWeb ? Requireme nt ?New Wizard. The problem is specific to all documents in a project, where the project has a requirement type where the name of the requiremen t type includes an '?' character.
Local fix
Problem summary
Customer is experiencing the following problem: "Runtime error - Object variable or with block variable not set" when editing a document via ReqWeb and tagging a new requirement. This error is thrown, if the user attempts to tag a requirement by either clicking on the Create Requirement button, going to RequisiteWeb ? Requirement ? New Mark, or RequisiteWeb ? Requirement ?New Wizard. The problem is specific to all documents in a project, where the project has a requirement type where the name of the requirement type includes an "?" character. To reproduce this behavior. - In a project, create a requirement type, with Name: "Functional ? Non-functional Reqs" (for example) - Any document in this project, will now experience this problem. So in ReqWeb, open any document and select Edit. - In the downloaded document, select text and try to create a new requirement (either clicking on the Create requirement button, or from the RequisiteWeb menu options) - The error will be thrown. Work-around: - Remove the "?" from the requirement type name.
Problem conclusion
Modified the Word Macros with a validation that will format the XML file that contain the Requirement types, because when the XML contain an "?" character it will not work, so the format will be change the "?" by "?amp;".
Temporary fix
Comments
APAR Information
APAR number
PM06437
Reported component name
REQUISITEPRO WI
Reported component ID
5724G3900
Reported release
701
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-29
Closed date
2010-06-23
Last modified date
2010-06-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
REQUISITEPRO WI
Fixed component ID
5724G3900
Applicable component levels
R701 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHCT","label":"Rational RequisitePro"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
23 June 2010