IBM Support

PM04509: IWN.VAL.9003.e - 0/0 - Generation terminated with v7.5

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment:
    - Windows XP
     - Rational Bussiness Developer v 75
    Reproducible Y/N: Y
    Description of problem:
    
    when generating code with the EGLSDK the same program which was
    successfully generated with RBD v7.1 now fails using RBD version
     7.5.
    
    EGL 7.5 batch generation fails:
    Some programs, which can be generated using version 7.1, fails u
    sing version 7.5.
    The error reported is like this:
    IWN.VAL.9003.e - 0/0 - Generation of FQ04A was terminated becaus
    e the reference to 'VDPASTC1' could not be resolved.
    (sometimes the reported part is another one).
    
    Step to reproduce:
    Workaround:
    

Local fix

Problem summary

  • When the target of a call statement is coded as a string
    literal, and this literal matches the name of a top level
    function (in this case, it was the same name as the function
    that contained the call statement), the IR was built
    incorrectly. This caused the error at generation time.
    

Problem conclusion

  • I have corrected the problem. You will need to force the
    program that is getting the error to recompile in order to
    fix the erroneous .IR file. I would suggest doing a clean
    build of the entire workspace, if possible.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM04509

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-06

  • Closed date

    2010-04-14

  • Last modified date

    2010-04-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R751 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
14 April 2010