APAR status
Closed as program error.
Error description
In case a class has a class type attribute as a member variable whose type is another class in the model, Reverse Engineering in RiJ omits its initialization code.
Local fix
Problem summary
When a class has a class type attribute whose type is another class in the model, the code that is regenerated after reverse engineering is missing initialization code.
Problem conclusion
Fixed in version 7.5.2.
Temporary fix
Comments
APAR Information
APAR number
PM03395
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-12-13
Closed date
2010-06-11
Last modified date
2010-06-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R750 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information