IBM Support

PK99241: Auto rollback when WAS http persistence session is on in RBD V7.1.0.4

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This defect is raised from ER: RATLC01487901.
    
    Client is using RBD V7.1.0.4 and WAS WAS ND V6.1.0.19 on AIX, th
    ey found when their WAS http persistence session is turn on, the
    ir EGL/Java application will get rollback exception automaticlly
    , although they have committed connection explicitly in EGL appl
    ication.
    
    development team has confirmed this is a defect in product in ER
    : RATLC01487901, and provided a testfix for client, which was te
    sted and accepted by client, so I raised this defect.
    

Local fix

Problem summary

  • When WAS Distribited environment settings are set to
    "Database", the database work used by JSF Handlers may be
    rolled back.  All changes will be lost.
    

Problem conclusion

  • When WAS Distribited environment settings are set to
    "Database", set the system property
    com.ibm.egl.noRollbackOnSerialize to true.
    
    To set the system property in WAS 6.1, start the
    administrative console.  Click Servers ? Application servers
    ? [server_name] ? Java and process management ? Process
    definition ? Java virtual machine ? Custom properties ? New.
     Name the new property com.ibm.egl.noRollbackOnSerialize,
    and enter true for the value.  The change will take effect
    after WAS is restarted.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK99241

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-10-22

  • Closed date

    2010-02-11

  • Last modified date

    2010-02-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
11 February 2010