A fix is available
APAR status
Closed as program error.
Error description
Environment: - Operating System: Microsoft Windows XP SP2, Sun Solaris - Product name: Rational Software Architect for WebSphere Soft ware 7.5.3, WebSphere Application Server Base Edition 7.0.0.3 Description of problem: WAS 7.0 / WAS 6.1 server library classpath container misses wsat lib.jar Step to reproduce: 1) Create an EJB project in RAD 7.0 targetting WAS 5.1. Referenc e a class com.ibm.wsif.format.jca.WSIFFormatPartImpl; 2) Migrate the project to RAD 7.5.3 / WAS 7.0 Result: Class com.ibm.wsif.format.jca.WSIFFormatPartImpl cannot be resol ved Workaround: Add to ?SDPShared?/plugins/com.ibm.ws.ast.st.core_6.2.1.v2009052 01310\v61RuntimeLst.txt a new line pointing to ?base_v61?/lib/ws atlib.jar Add to ?SDPShared?/plugins/com.ibm.ws.ast.st.core_6.2.1.v2009052 01310\v7RuntimeLst.txt a new line pointing to ?base_v7?/com.ibm. ws.wsadie/wsatlib.jar
Local fix
Problem summary
Classes from wsatlib.jar used for compilation of legacy code were not available in the workbench which targetted WAS 6.1 and WAS7.0 servers. That has been fixed for RAD 7.55
Problem conclusion
Fixed in Rational Application Developer V7.5.5
Temporary fix
Comments
APAR Information
APAR number
PK97512
Reported component name
RATL APP DEV WI
Reported component ID
5724J1901
Reported release
753
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-09-30
Closed date
2009-12-17
Last modified date
2009-12-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL APP DEV WI
Fixed component ID
5724J1901
Applicable component levels
R753 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.3","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]