Error description
Summary: 225996 -------- SBS file missing on migration and gets erraneous when included to the model Description: ----------- Migration of model from 7.3 to 7.5 has a missing unit and inturn is affecting many models in various ways From 7.3 to 7.5 the model was migrated Model is on Clear Case 6.x Model checked from 7.3 Rhapsody Model checked out into 7.5 Rhapsody 1. There is a SBS file missing when they perform checkout Scenario1: ----------- If they do Add to Model as UNIT The user defined icons disappear and they all get back to the original Rhapsody icons On Save almost all the userdefined icons appear, except the BDD (Block definition Duagram) icon Scenario2: ---------- If they Add to Model as REFERENCE Rhapsody Crashes Scenario3: ---------- This SBS file can be opened in the new project and it seems to work fine and all the elements get loaded without any issues. Additional Information: ----------------------- Property files are default, custom made also make the same behavior Functionality of the SBS file in concern: This SBS file has many usecases and activity diagrams with call behaviors and other elements. They have numerous references to other elements. Client Business Impact: ----------------------- HHH They need immidiate relief as they need to decide on migration tomoro. DEADLINE - 11th August CUSTOMER CANNOT SHARE THE MODEL/MODEL ELEMENTS/CRASH FILES WITH US. PMR : 61048,003,756
Local fix
NA
Problem summary
RAFAEL: APAR: PK93517 :SBS file missing on migration and gets erraneous when included to the model (pending on security clearance)
Problem conclusion
Fixed in 7.5.1.1
Temporary fix
Comments
APAR Information
APAR number
PK93517
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-08-10
Closed date
2010-03-22
Last modified date
2010-03-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R750 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
22 March 2010