A fix is available
APAR status
Closed as program error.
Error description
Environment: Rational Business Developer v7.1.1.3 Variable file records are not created correctly. VB records when the record length is reset takes the initial setting only. Example: EBILL is a VB dataset. Record R01 type serialRecord { fileName = 'EBILL', lengthItem = DRECL .. } Record R00 type serialRecord { fileName = 'EBILL', lengthItem = HRECL } Header is written first in function N24P_HEADER_ADD() ... sets the HRECL to 48. Detail is written in function P03()... sets the DRECL to 942. However the detail records are truncated to 48. When the EGL code is adjusted to HRECL = 942... there is no trun cation in the detail record.
Local fix
Problem summary
The generator was not checking for multiple records, with multiple lengthitems being used, for the same file
Problem conclusion
Software updated. Fixtest available.
Temporary fix
Comments
APAR Information
APAR number
PK85326
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-24
Closed date
2009-07-23
Last modified date
2009-07-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R750 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
06 December 2021