A fix is available
APAR status
Closed as program error.
Error description
DOORS-QC integration checks out DOORS license instead of DCTD license and thus renders one DOORS license unusable during the synch.DOORS license is not released even after synchronization is completed.
Local fix
kill doors.exe process manually
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** DOORS-QC integration checks out DOORS license instead of DCTD license and thus renders one DOORS license unusable during the synch
Problem conclusion
The code has been changed so that correct license is checked out
Temporary fix
Comments
APAR Information
APAR number
PK84905
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-17
Closed date
2011-08-03
Last modified date
2011-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R910 PSN
UP