IBM Support

PK84815: MESSAGE QUEUE DOES NOT PEND CORRECTLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 223642
    
    This problem occurs in at least two implementations of the
    OMOSMessageQueue, namely the Windows and INTEGRITY
    implementations.
    Let's say a queue has one item in it. Call Pend() and it returns
    immediately since the queue is populated. Call Get() on the
    queue to receive the item.
    
    Call Pend() again. It should *not* return now because the queue
    is empty. But it does return, immediately. This is the problem.
    

Local fix

  • Modify code by hand.
    

Problem summary

  • Message Queue does not pend correctly.
    

Problem conclusion

  • Fixed in 7.5.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK84815

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    740

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-16

  • Closed date

    2009-12-03

  • Last modified date

    2009-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R740 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.4","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: