IBM Support

PK84797: RATIONAL BUSINESS DEVELOPER V7.1.0: NULLPOINTEREXCEPTION GENERATING COBOL PROGRAMS WITH VARIABLE LENGTH SERIAL RECORDS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rational Business Developer V7.1.0.3:
    
    NullPointerException generating COBOL programs with variable
    length serial records.
    
    A NullPointerException may occur when the definition of a serial
    variable length record is made, and the variable length field
    points at a structured field that is not at the top level in the
    structured record and the structured record has not been defined
    in the EGL source until after the definition of the serial
    record.
    

Local fix

  • A fix test is available from support on request.
    

Problem summary

  • A nullpointer exception could happen if the serial record is
    referencing a length variable, and that length variable is
    in a record that has not as yet been analyzed in the source
    (further down in the source code) and the length field is
    not at the highest level in the record.
    

Problem conclusion

  • Software updated. Fixtest available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK84797

  • Reported component name

    RBD EGL FOR COB

  • Reported component ID

    5724S5001

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-16

  • Closed date

    2009-07-23

  • Last modified date

    2009-07-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RBD EGL FOR COB

  • Fixed component ID

    5724S5001

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
07 December 2021