PK84499: calling a DL/I module on z/OS from within the EGL Debugger, an S 0C1 ABEND occurs

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment: Windows XP SP3
    
    Product name: IBM? Rational? Business Developer
    
    Program Version    :  7.1.0.2
    2.Problem Description. Things that you have tried to resolve.
    There is an error with the EGL debugger producing an abend when
    calling AIBTDLI program
    When calling a DL/I module on z/OS from within the EGL Debugger,
     an S0C1 ABEND occurs.
    
    The error message is output via dialog box ie:
    JavartException: ABEND occured on remote Host.
    
    This involves a scenario with  main programs that each call a 3r
    d program.
    The called program will receive ?SOME? PCB to an IMS dbase, rega
    rdless from the originating PSB in the called program. This mean
    s that neither PCB-position, nor PCB-label are fixed.
    
    The problem is actually a generation problem, the EGL generated
    code in the called program receives the PCB that is passed in, b
    ut then does an inquiry against the scheduled DB using the PCB n
    ame in the PSB. The PCB returned by the inquire will replace the
     1 that is passed in, the 1 that was passed in contained informa
    tion used by the debugger code. Since the debugger information w
    as overwritten the call to DLI will fail. The generated code sho
    uld not be overwritting the PCB that was passed in.
    

Local fix

Problem summary

  • The generated AIB code was trying to initialize a PCB that
    was passed into the program.
    

Problem conclusion

  • changed the generated code so it uses the passed in PCB
    record.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK84499

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-10

  • Closed date

    2009-07-24

  • Last modified date

    2009-07-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
06 December 2021