APAR status
Closed as program error.
Error description
Environment: - Windows XP PRO - Rational Bussiness Developer Extension 751 Reproducible Y/N: Y Description of problem: EGL generation fails with java.lang.NullPointerException Generation of sintatically correct (no errors in the editor) EGL TUI program fails with an error message: IWN.VAL.9994.i 1/1 Generating part logic.TUIprogram with build descriptor TestProjectCOBOLBuildOptions from file \TestProject\EGLSource \TestProject.eglbld. IWN.VAL.9999.e 0/0 Stack Trace: java.lang.NullPointerException IWN.VAL.9999.e 0/0 Stack Trace: at com.ibm.etools.egl.generation.cobol.analyzers.factories.Expressi onSource Step to reproduce: Workaround:
Local fix
Problem summary
The IF statement for IN and a literal array was not working correctly. This has been fixed in both 7512 and 7103. Circumvention is to code the array literal as an EGL array variable, and then do IF IN on the variable.
Problem conclusion
Software updated
Temporary fix
Comments
APAR Information
APAR number
PK81601
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-02
Closed date
2009-04-13
Last modified date
2009-04-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R700 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information