A fix is available
APAR status
Closed as program error.
Error description
Rational COBOL Runtime for zSeries V.6.0.1: Whenever a CICS AOR is recycled, hundreds of ABEND AEYH, in module ELATSRST, are received. CICS is recycled with SIT parameter TS= (COLD,x,y) or TS QUEUEs are cleared nightly by a customized routine. This ABEND appears to be caused by the fact that all temporary storage queues are lost and the runtime cannot get the information stored for controlling the pseudo conversation.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: RDB USERS * **************************************************************** * PROBLEM DESCRIPTION: CICS ABEND AEYH WHEN RUNNING RATIONAL * * COBOL RUNTIME FOR ZSERIES * **************************************************************** * RECOMMENDATION: APPLY THIS MAINTENANCE. * * WHENEVER A CICS AOR IS RECYCLED, HUNDREDS * * OF ABEND AEYH, IN MODULE ELATSRST, ARE * * RECEIVED. CICS IS RECYCLED WITH SIT * * PARAMETER TS= (COLD,X,Y) OR TS QUEUES ARE * * CLEARED NIGHTLY BY A CUSTOMIZED ROUTINE. * * THIS ABEND APPEARS TO BE CAUSED BY THE FACT * * THAT ALL TEMPORARY STORAGE QUEUES ARE LOST * * AND THE RUNTIME CANNOT GET THE INFORMATION * * STORED FOR CONTROLLING THE PSEUDO * * CONVERSATION. * **************************************************************** WHENEVER A CICS AOR IS RECYCLED, HUNDREDS OF ABEND AEYH, IN MODULE ELATSRST, ARE RECEIVED. CICS IS RECYCLED WITH SIT PARAMETER TS= (COLD,X,Y) OR TS QUEUES ARE CLEARED NIGHTLY BY A CUSTOMIZED ROUTINE. THIS ABEND APPEARS TO BE CAUSED BY THE FACT THAT ALL TEMPORARY STORAGE QUEUES ARE LOST AND THE RUNTIME CANNOT GET THE INFORMATION STORED FOR CONTROLLING THE PSEUDO CONVERSATION.
Problem conclusion
WHENEVER A CICS AOR IS RECYCLED, HUNDREDS OF ABEND AEYH, IN MODULE ELATSRST, ARE RECEIVED. CICS IS RECYCLED WITH SIT PARAMETER TS= (COLD,X,Y) OR TS QUEUES ARE CLEARED NIGHTLY BY A CUSTOMIZED ROUTINE. THIS ABEND APPEARS TO BE CAUSED BY THE FACT THAT ALL TEMPORARY STORAGE QUEUES ARE LOST AND THE RUNTIME CANNOT GET THE INFORMATION STORED FOR CONTROLLING THE PSEUDO CONVERSATION.
Temporary fix
Comments
APAR Information
APAR number
PK81361
Reported component name
ED SERVER FOR Z
Reported component ID
5655I5700
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-02-25
Closed date
2009-04-10
Last modified date
2009-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ELATSRST
Fix information
Fixed component name
RATL COBOL RT Z
Fixed component ID
5655R2900
Applicable component levels
R601 PSY UK45676
UP09/04/15 P F904
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSN27B","label":"Rational COBOL Runtime for zSeries"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 May 2009