IBM Support

PK79051: WEB TRANSACTION FAILS ON CICS WITH ABEND ELAX ELA09973

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Web Transaction that contains recurive egl function abends with
    ELAX 9973, when trying to converse a UI record. The problem happ
    ens when trying to run the MRSHLO (marshall-out) function needed
     for the converse.
    

Local fix

Problem summary

  • When a webtransaction under cics has a recursive routine
    that also uses the EZECSO-GWS-OUT-BLOCK control block, the
    addressability of that control block is lost, due to the
    CALL statement instead of the PERFORM. This causes an abend
    in the application.
    

Problem conclusion

  • Software updated. Fixtest EGLFixtest200901202228 is
    available for 7102 systems
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK79051

  • Reported component name

    RBD EGL FOR COB

  • Reported component ID

    5724S5001

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-01-20

  • Closed date

    2009-03-20

  • Last modified date

    2009-03-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RBD EGL FOR COB

  • Fixed component ID

    5724S5001

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: