IBM Support

PK68467: JSP editor : layout designer flips justification

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • Using Rational Application Developer 7.0.0.6, on customizing the
    screen by moving table cell element, re size table cell element
     or delete table cell element causes the page to reverse the jus
    tification.
    Any action that is effecting table cell dimensions.
    The effect of the screen is the whole page flip justification. R
    ight to left, and left to right.
    Step to reproduce:
    - Create a JSP page, create a Free Layout Table(FLT) and drop a
    few HTML controls within the free layout table
    - Set ?body dir='rtl'? on the body tag.
    - Try to relocate any HTML element within the FLT to a different
     position by dragging it. As a result the whole layout will be f
    lipped. Then try to relocate the same widget again, and the whol
    e layout will be flipped back again. In conclusion: dir=rtl tag
    on ?BODY? causes this problem.
    Workaround:
    This is a Page Designer problem with Free Layout Table when you
    set dir='rtl' for this table.
    To work around this you have to replace Free Layout  table with
    a normal table.
    

Local fix

Problem summary

  • Issue is fixed indirectly in 7.0.0.8 and no longer reproducible
    in this version.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PK68467

  • Reported component name

    RATL APP DEV WI

  • Reported component ID

    5724J1901

  • Reported release

    700

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-07-02

  • Closed date

    2008-12-15

  • Last modified date

    2008-12-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL APP DEV WI

  • Fixed component ID

    5724J1901

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
15 December 2008