Error description
Problem Descriptions: 1) Multiple HDB Profiling report requests may generate JCL with the HDB Container DD name list in incorrect sequence. 2) No HDB containers are selected and message CPA1044E is displayed when "TO" time is not specified in Profiling report panels. 3) "TO" time defaults to start-of-day instead of end-of-day in the following functions: - Selection Criteria - HDB Extract - HDB Report 4) ABEND0CF in OMEGAMON report at CPAOMGMF+6386 when DB option is selected without TOTALS option. 5) Fields TERMCNNM, FCTY, LUNAME and RLUNAME missing from Summary FORM and TEMPLATE. 6) Statistics View Node count not always correct. 7) Summary report MIN value not always correct. 8) TRANTYPE Selection Criteria does not select records unless an exact match is specified for TRANTYPE of combined values, e.g. transactions of TRANTYPE Mirror transaction and DPL mirror transaction require MD in the selection criteria. Specifying M or D in the Selection Criteria does not select these transactions. 9) Sample FORMS enhancements.
Local fix
Problem Resolutions: 1) Selection of multiple overlapping Profile reports using HDB now generates the list of HDB containers in the correct sequence. 2) Profiling report HDB "TO" time now defaults to end-of-day when not specified, thus allowing the correct list of HDB containers to be selected. 3) Default "TO" time to end-of-day instead of start-of-day when "TO" time is not specified in the following functions: - Selection Criteria - HDB Extract - HDB Report 4) Correct OMEGAMON report ABEND0CF when option DB is selected without TOTALS option. 5) Add CMF fields TERMCNNM, FCTY, LUNAME and RLUNAME to Summary FORM and TEMPLATE. 6) Correct Statistics View Node to display correct node count. 7) Correct Summary report MIN value. 8) TRANTYPE Selection Criteria has been modified to allow the specification of individual values so the user gets all the transactions with specified value regardless of what other values are also set. If the user only wants a specific combination, e.g DM, they specify DM, etc. Of course the user can also specify a list, e.g. DM,R,O. In addition, value U (TRANTYPE User, i.e. not System) is also now supported in the TRANTYPE Selection Criteria. 9) Sample FORMS have enhanced as follows: OMRLMLST LIST split into :- OMDLMLST LIST OMEGAMON Database Limit Warnings OMRLMLST LIST OMEGAMON Resource Limit Warnings New FORM PGDPLSUM SUMMARY DPL Program Usage by Connection FORM CPU3LEXT contained X9CPU TIME twice. The second entry has been replaced with X9CPU COUNT.
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS Performance Analyzer. * **************************************************************** * PROBLEM DESCRIPTION: To resolve the problems detailed in the * * summary. * **************************************************************** * RECOMMENDATION: * **************************************************************** The following problems have been resolved: 1. Multiple HDB Profiling report requests may generate JCL with the HDB Container DD name list in incorrect sequence. 2. No HDB containers are selected and message CPA1044E is displayed when "TO" time is not specified in Profiling report panels. 3. "TO" time defaults to start-of-day instead of end-of-day in the following functions: - Selection Criteria - HDB Extract - HDB Report 4. ABEND0CF in OMEGAMON report at CPAOMGMF+6386 when DB option is selected without TOTALS option. 5. Fields TERMCNNM, FCTY, LUNAME and RLUNAME missing from Summary FORM and TEMPLATE. 6. Statistics View Node count not always correct. 7. Summary report MIN value not always correct. 8. TRANTYPE Selection Criteria does not select records unless an exact match is specified for TRANTYPE of combined values, e.g. transactions of TRANTYPE Mirror transaction and DPL mirror transaction require MD in the selection criteria. Specifying M or D in the Selection Criteria does not select these transactions. 9. Sample FORMS enhancements. 10. Intermittent ISPF abend ISPF107 when submitting a Report Set with the following symptom: Control word error Invalid control word parameter, CPARSJCS record-72 File tailoring input line: 'close paenthesis'DOT &HDBTAB 11. The Exception List report prints the same date and time of the earliest record in all page headers of report. This makes it difficult to determine the date of individual records when the report spans multiple days. 12. The Statistics Extract and DB2 Export data lacks sufficient information to identify the interval a records belongs to.
Problem conclusion
The following changes have been made: 1. Selection of multiple overlapping Profile reports using HDB now generates the list of HDB containers in the correct sequence. 2. Profiling report HDB "TO" time now defaults to end-of-day when not specified, thus allowing the correct list of HDB containers to be selected. 3. Default "TO" time to end-of-day instead of start-of-day when "TO" time is not specified in the following functions: - Selection Criteria - HDB Extract - HDB Report 4. Correct OMEGAMON report ABEND0CF when option DB is selected without TOTALS option. 5. Add CMF fields TERMCNNM, FCTY, LUNAME and RLUNAME to Summary FORM and TEMPLATE. 6. Correct Statistics View Node to display correct node count. 7. Correct Summary report MIN value. 8. TRANTYPE Selection Criteria has been modified to allow the specification of individual values so the user gets all the transactions with specified value regardless of what other values are also set. If the user only wants a specific combination, e.g. DM, they specify DM, etc. Of course the user can also specify a list, e.g. DM,R,O. In addition, value U (TRANTYPE User,) i.e. not System. is also now supported in the TRANTYPE Selection Criteria. 9. Sample FORMS have enhanced as follows: a. OMRLMLST LIST split into :- OMRLMLST LIST OMEGAMON Resource Limit Warnings b. New FORM PGDPLSUM SUMMARY DPL Program Usage by Connection. c. FORM CPU3LEXT contained X9CPU TIME twice. The second entry has been replaced with X9CPU COUNT. d. FORM CPU3SEXT updated to include MAX values for various cpu fields. 10. Fix intermittent ISPF abend ISPF107 when submitting Report Sets. 11. The Exception List report has been modified to print the date and time of the first record in each page, thus making easier to determine the date of individual records when the report spans multiple days. 12. Statistics Extract and DB2 Export data enhanced to include additional interval fields VRM, Type, Duration and Number to assist in identification of individual intervals. See ++HOLD data for impact information. 210Y CPAELECT CPAHDEST CPAHDHDR CPAHDHST CPAHDOLI CPAHDSEL CPAHDSTA CPAHDSTR CPAHDXPJ CPAHDXST CPAHSBLD CPAHSSDD CPAHSSDP CPAIBM$0 CPAJCL CPAOMGMF CPARFNEW CPARFSAM CPARSJCL CPASUMMF CPAXCPMF
Temporary fix
Comments
APAR Information
APAR number
PK60975
Reported component name
CICS PERF ANALY
Reported component ID
5697N4000
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-02-13
Closed date
2008-03-11
Last modified date
2008-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK34420
Modules/Macros
CPAELECT CPAHDEST CPAHDHDR CPAHDHST CPAHDOLI CPAHDSEL CPAHDSTA CPAHDSTR CPAHDXPJ CPAHDXST CPAHSBLD CPAHSSDD CPAHSSDP CPAIBM$0 CPAJCL CPAOMGMF CPARFNEW CPARFSAM CPARSJCL CPASUMMF CPAXCPMF
GC34688301 |
Fix information
Fixed component name
CICS PERF ANALY
Fixed component ID
5697N4000
Applicable component levels
R210 PSY UK34420
UP08/03/15 P F803
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPU4","label":"CICS Performance Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 April 2008