Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 7 users.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. IDI0120S IBM Fault Analyzer         *
    *                          internal abend S0C4 at entry point  *
    *                          prtSynopsis offset X'5974' during   *
    *                          printing of the Synopsis section of *
    *                          the analysis report.                *
    *                          APAR PK51492                        *
    *                      02. Incorrect dump code reported in     *
    *                          CICS transaction fault analysis     *
    *                          report.                             *
    *                          APAR PK50166                        *
    *                      03. Attempting V line command against a *
    *                          fault entry results in "reanalysis  *
    *                          not possible" message.              *
    *                          APAR PK50761                        *
    *                      04. REXX Notification user exit not     *
    *                          always executing; IRXEXEC RC=20.    *
    *                          APAR PK51930                        *
    *                      05. Message IDI0047S abend S0C4 at      *
    *                          entry point usrhdlr_check offset    *
    *                          X'354'.                             *
    *                          APAR PK51294                        *
    *                      06. IMS BMP region hung, waiting for    *
    *                          ENQ on major name SYSIDIDA minor    *
    *                          name SYSOUT.                        *
    *                          APAR PK51292                        *
    *                      07. Exception in CEEPLPKA after CICS    *
    *                          startup or after a Fault Analyzer   *
    *                          NoDup(CICSfast) duplicate.          *
    *                          APAR PK52009                        *
    *                      08. IDI0092S time-out from Fault        *
    *                          Analyzer with a very large COBOL    *
    *                          listing.                            *
    *                          APAR PK52367                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. The success or failure of an internal function call was not
        being correctly checked.
    02. Fault Analyzer was incorrectly determining that an EXEC CICS
        DUMP request had been issued when invoked in the XDUREQ
        Global User Exit.
    05. Invalid storage was being referenced.
    06. An ENQ issued earlier during analysis of an abend in the
        IEFIIC initiator TCB was still active.
    07. A parameter list of 00000000 was being passed on an
        ATTACH of IDICCFND, which was causing errors during LE
        initialization.
    08. Fault Analyzer processing of a very large COBOL listing for
        IDILANGX processing from a real time abend can get message
        IDI0092S because of the extended time required.
    

Problem conclusion

  • 01. The code has been altered accordingly.
    02. Dumps with code AFCI are now reported as transaction dumps
        instead of EXEC CICS DUMP.
    03. The incorrect condition has been fixed to allow a saved
        report to be viewed correctly.
    04. IDIEXEC is now correctly allocated prior to invocation of
        the REXX Notification user exit.
    05. A check has been added to ensure that the storage referenced
        is valid.
    06. Fault Analyzer has been excluded from performing analysis of
        abends in the IEFIIC initiator TCB.
    07. The code has been changed to pass an LE conforming null
        parameter list instead of 00000000.
    08. The call to IDILANGX to process listings for source code
        analysis, has extended time allowed before loop protection
        time-out will occur.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK49788

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655R4600

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-07-27

  • Closed date

    2007-08-22

  • Last modified date

    2007-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655R4600

Applicable component levels

  • R710 PSY UK28921

       UP07/09/12 P F709

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 October 2007