PK40728: UNABLE TO CONNECT TO LOCAL WEBSPHERE APPLICATION SERVER USING RMI WHEN NETWORK CONNECTIVITY HAS BEEN LOST.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using the RMI connection to WAS the client connection can
    fail.
    To reproduce:
    1) Plug a laptop into network and start AST v6.1.
    2) Define a new WAS v6.1 server and verify that you can start it
    and the status appears correctly in the Servers view.
    3) Stop the server.
    4) Unplug the network connection.
    5) Start WAS v6.1 - note that the server status stays as
    Starting... and will eventually timeout.
    6) Switch to SOAP, and it can connect to the server.
    7) Switch back to RMI, and the client fails again as the server
    status goes back to Stopped.
    8) Restart AST, and RMI will work again.
    Tracing activity shows the following exception:
    com.ibm.ws.orbimpl.transport.WSTCPTransportConnection
    connect:403 WAS communication ORBRas[default]
    java.net.NoRouteToHostException: No route to host: connect
    at java.net.PlainSocketImpl.socketConnect(Native Method)
    at java.net.PlainSocketImpl.doConnect(PlainSocketImpl.java:372)
    at
    java.net.PlainSocketImpl.connectToAddress(PlainSocketImpl.java:2
    33)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users using the version 6.1 WebSphere    *
    *                 Application Server runtime in Rational       *
    *                 Application Developer v7.0 and WebSphere     *
    *                 Application Server Toolkit v6.1              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The connection to the version6          *
    *                      WebSphere Application Server runtime    *
    *                      is lost when using RMI as the connector *
    *                      and the localhost network address       *
    *                      changes.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If a computer is connected to a wired network and a version6
    WebSphere Application Server runtime is being used via the RMI
    connector when the network changes (for example, to a wireless
    network) then the connection to the server is permanently lost
    in Rational Application Developer and WebSphere Applicatoin
    Server Toolkit.
    

Problem conclusion

  • The JVM name lookup cache policy for Rational Application
    Developer and WebSphere Application Server Toolkit has been
    modified to cache the hostname for only 1 second.  Therefore,
    if the address changes for the local adaptor then the
    connection will re-establish after 1 second.
    
    The fix for this APAR is currently targeted for inclusion in
    Rational Application Developer v7.0.0.3 and WebSphere
    Application Server Toolkit v6.1.1.3.  Please refer to the
    Recommended Updates page for WebSphere Application Server
    Toolkit delivery information:
    http://www.ibm.com/support/docview.wss?uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK40728

  • Reported component name

    WEBAPP SERVER A

  • Reported component ID

    5724J0820

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-03-07

  • Closed date

    2007-04-05

  • Last modified date

    2007-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBAPP SERVER A

  • Fixed component ID

    5724J0820

Applicable component levels

  • R610 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
19 October 2021