IBM Support

PK39637: Struts Config File Editor scope scroll-down box option not writt en to source

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Using Rational Application Developer V7.0.0.1
    In struts-config.xml ? Action Mappings ? under Form Bean Specifi
    cation, when you select a form bean name and then the scope, the
     value in the Scope cannot be saved. If you select request or re
    sponse, Save the config file, close. And then re-open, the scope
     would become blank again. If you go to source at any point afte
    r choosing req/resp, the source does not reflect this selection
    either.
    Problem is reproducible by the following:
    a) open new struts project ? make sure necessary struts function
    s are enabled
    b) file ? new ? others ? struts ? actionForm
    c) open struts-config.xml with Struts Config File Editor.
    d) Action Mappings ? add an Action Mapping
    e) go to Form Bean Specification, point to the form you just cre
    ated.
    f) change Scope
    After this, the Source is not updated. You can save the file and
     close. When you reopen it and click the same action-mapping, th
    e scope would remain blank.
    

Local fix

Problem summary

  • The scope of a formbean for an action mapping when set to
    "request" from the GUI was not getting set in the model.
    

Problem conclusion

  • Fixed to update the model when the scope is set to
    "request".
    Fix delivered in Rational Application Developer V7.0.0.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK39637

  • Reported component name

    APP DEV V6 WIN

  • Reported component ID

    5724J1901

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-02-19

  • Closed date

    2007-07-09

  • Last modified date

    2007-07-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP DEV V6 WIN

  • Fixed component ID

    5724J1901

Applicable component levels

  • R600 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
19 October 2021