A fix is available
APAR status
Closed as program error.
Error description
When inlining PERFORM statements that are PERFORMed exactly once, the compiler may incorrectly update its internal state, leading to a future abend. Compile terminates with IGYIN5125-U The compilation was terminated due to a compiler error in phase id: "IGYCINIT".
Local fix
Compile using OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling * * programs at OPT(1|2) that contain * * paragraphs that appear in exactly one * * PERFORM statement and are not reachable * * through top-to-bottom flow through the * * program. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with message * * MSGIGYIN5125-U The compilation was * * terminated due to a compiler error in * * phase id: "IGYCINIT". * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** When inlining PERFORM statements that are PERFORMed exactly once, the compiler may incorrectly update its internal state, leading to a future abend.
Problem conclusion
The compiler was fixed to correctly update its internal state when inlining PERFORM statements that are PERFORMed exactly once.
Temporary fix
Comments
APAR Information
APAR number
PI97628
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-04
Closed date
2018-05-28
Last modified date
2018-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCDOPT IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI56120
UP18/06/01 P F805
R621 PSY UI56121
UP18/06/01 P F805
R622 PSY UI56122
UP18/06/01 P F805
R62H PSY UI56123
UP18/06/01 P F805
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023