A fix is available
APAR status
Closed as program error.
Error description
COBOL V6.1 Compiler error at OPT(1|2): IGYCB7104-U Internal error while compiling function XXXXXX. Failed assertion on analyses/Dominators.cpp:117. Compilation terminated. -------------------------------------------------------- Assertion failed at analyses/Dominators.cpp:117: false Unreachable block in the CFG 371 374
Local fix
Compile at OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.1 compiling * * programs with PERFORM statements that can * * reach themselves, using INITCHECK. * **************************************************************** * PROBLEM DESCRIPTION: Compiler ABORT with message * * MSGIGYCB7104-U: Internal error while * * compiling function XXXXXX. Failed * * assertion on * * analyses/Dominators.cpp:117. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** In some rare cases, when PERFORM statements cause infinite loops by reaching themselves, the code that allows INITCHECK to identify which data items are initialized by each PERFORM statement cannot properly identify which lines of code will be executed by a PERFORM.
Problem conclusion
The compiler was modified to handle those rare cases more gracefully.
Temporary fix
Comments
APAR Information
APAR number
PI97404
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-04-30
Closed date
2018-06-18
Last modified date
2018-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R610 PSY UI56627
UP18/06/21 P F806
R611 PSY UI56628
UP18/06/22 P F806
R612 PSY UI56629
UP18/06/22 P F806
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: