APAR status
Closed as program error.
Error description
Developer for System z - IDz - v14.1 Description : When opening a Cobol source and then using the clone editor to have the same source edited, if you modify the 1st source, after the CTRL+ Save, the outline view of the clone is not updated. The outline view is only updated for the editor version where the change was made and saved.
Local fix
If a space is added and removed from the file and the file is saved, the outline view is then updated.
Problem summary
When opening a Cobol or PL1 file and then cloning the editor to have the same source edited, if you modify the 1st source, after the CTRL+ Save, the outline view of the clone is not updated. The outline view is only updated for the editor version where the change was made and saved.
Problem conclusion
A code change was made in how the outline view is updated.
Temporary fix
Comments
APAR Information
APAR number
PI96241
Reported component name
DEV FOR Z SYS
Reported component ID
5724T0700
Reported release
E10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-04-05
Closed date
2018-06-14
Last modified date
2018-06-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z SYS
Fixed component ID
5724T0700
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
27 October 2020