IBM Support

PI95832: INTERNAL COMPILER GRARNN ERROR WITH INLINE AND HGPR

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When compiling an application with the INLINE and
    HGPR(NOPRESERVE) compiler options, an internal compiler error is
    encountered:
    
    
       SEVERE ERROR CCN1104: Internal error while compiling function
       <function_name>.  GRARNN: gr3754 is used before it is
       defined.  Compilation terminated.
    
    
    The issue is triggered by using larger than default INLINE
    suboptions, for example:
    
    
       INLINE(AUTO,REPORT,1000,100000)
    
    
    When compiling with the LIST option, the following error may be
    seen in the LIST output:
    
    
       GRARNN: gr3754 used before defined gr3754 at:
       16027:      UDIV8    *gr7019,*gr7018=gr9770,gr7015,gr3754
    

Local fix

  • Lower the INLINE threshold value:
    
       INLINE(AUTO,REPORT,100,10000)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: z/OS XL C/C++ V2R1 and V2R2                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Internal compiler error when compiling  *
    *                      with ARCH(7) or higher, HGPR and        *
    *                      NOXPLINK                                *
    ****************************************************************
    .
    

Problem conclusion

  • Apply service provided.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI95832

  • Reported component name

    C/C++ FOR MVS

  • Reported component ID

    56551210A

  • Reported release

    791

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-03-27

  • Closed date

    2018-03-29

  • Last modified date

    2018-08-01

  • APAR is sysrouted FROM one or more of the following:

    PI79943

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CCNECICS CCNECWI  CCNED211 CCNEDSCT CCNEDWRT CCNEFILT CCNEHIFC
    CCNEMDEP CCNEOPTP CCNEP    CCNEPP   CCNETBY  CCNMSGE  CCNMSGT
    

Fix information

  • Fixed component name

    C/C++ FOR MVS

  • Fixed component ID

    56551210A

Applicable component levels

  • R791 PSY UI54849

       UP18/04/25 P F804

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"791","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQKCWV","label":"IBM C\/C++ for MVS\/ESA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"791","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]