Fixes are available
APAR status
Closed as program error.
Error description
STEPS TO REPRODUCE : - Make sure to have many RQM projects (> 20 or 50) - Configure your RIT RQM adapter so that it points to a RQM project that does not come out of the first returned page from the RQM REST API to query projects - Go to RQM and check the Adapter view for your configured RIT RQM adapter EXPECTED RESULTS : You would expect your new RIT RQM adapter to be listed in the Adapter view ACTUAL RESULTS : Your RIT RQM adapter does not show in the list and in the RIT Agent log, you get an error of type : SEVERE: Unable to connect: Failed to resolve project alias WORKAROUND : You have to rename your RQM project so that is appears in the first RQM REST API returned page of RQM project for the RIT RQM adapter to get listed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Integration Tester and Rational Quality * * Manager * **************************************************************** * PROBLEM DESCRIPTION: * * The Rational Quality Manager Adapter will fail to start if * * there are more than 50 project areas defined and the * * configured project is not in the first 50. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in 9.2.1.
Temporary fix
Comments
APAR Information
APAR number
PI95099
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
911
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-13
Closed date
2018-10-03
Last modified date
2018-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSN
UP
R920 PSN
UP
R921 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"911","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
19 October 2021