A fix is available
APAR status
Closed as program error.
Error description
Compile gives failed assertion on /build/cob/5.2/tr.r14.cobol-prod-opt/tr.source/il/node/TRNodeBas e.hpp:707.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling * * programs that have a PERFORM UNTIL * * statement that compares the same data item * * to multiple values or has a condition-name * * with multiple values. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abort with message * * MSGIGYCB7104-U Internal error while * * compiling function XXXXX. Failed * * assertion on * * /build/cob/5.2/tr.r14.cobol-prod- * * opt/tr.source/il/node/TRNodeBase.hpp:70 * * 7. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler was optimizing multiple compares of the same data item or compares to verify a condition-name with multiple values in a way that caused the compiler's internal state to become incorrect if the compares were part of a PERFORM UNTIL statement.
Problem conclusion
The compiler was fixed to avoid optimizing multiple compares of the same data item or compares to verify a condition-name with multiple values if the compares are part of a PERFORM UNTIL statement.
Temporary fix
Comments
APAR Information
APAR number
PI92505
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-01-16
Closed date
2018-01-19
Last modified date
2018-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCDOPT IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYMSGXT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI53355
UP18/01/27 P F801
R621 PSY UI53356
UP18/01/27 P F801
R622 PSY UI53357
UP18/01/27 P F801
R62H PSY UI53358
UP18/01/27 P F801
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023