A fix is available
APAR status
Closed as program error.
Error description
With the additional optimization that COBOL v5+ does, code may be eliminated under TRUNC(OPT) based on the maximum number of decimal digits in a non-native binary (BINARY, COMP, COMP-4) data item, code that was not eliminated under the previous compilers.
Local fix
Compile with OPT(0) or TRUNC(BIN).
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling and * * running programs that are compiled with the * * OPT(1|2) and TRUNC(OPT) options and have a * * binary data item (i.e., USAGE BINARY, COMP, * * or COMP-4) that contains data that does not * * conform to its PIC clause. * **************************************************************** * PROBLEM DESCRIPTION: Migration issue/Incorrect runtime * * results. Results of execution can be * * different from previous compilers when * * TRUNC(OPT) is used without following * * the rules for TRUNC(OPT) which require * * the data to not exceed the maximum * * number of digits in the PICTURE clause * * definition of the data item. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler was sometimes inadvertently assuming that binary data items conform to their PIC clause for programs compiled with TRUNC(OPT) and OPT(1|2).
Problem conclusion
The compiler was updated to ensure that for programs compiled with TRUNC(OPT) there is never an assumption made that binary data items conform to their PIC clause. This will ease migration from pre-V5 compilers to V6.
Temporary fix
Comments
APAR Information
APAR number
PI90560
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-22
Closed date
2017-11-27
Last modified date
2018-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYSIDEK IGYZQDRV
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UP
A
R621 PSY UP
A
R622 PSY UI56122
UP18/06/01 P F805
R62H PSY UP
A
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: