PI87855: IN THE GATEWAY DAEMON ANY IOEXCEPTION RESULTING FROM THE HANDSHAKE IS CAUGHT AND TRACED, BUT NOT LOGGED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • On the CICS TG client side the reason for the connection failure
    is recorded by the "java.io.IOException CTG6651E "Unable to
    connect to the Gateway  daemon:
    &#172;address/port|&#172;javax.net.ssl.SSLHandshakeException:<reason>|."
    message
    
    In the Gateway daemon any ioexception resulting from the
    attempted SSL handshake is caught and traced, but not logged.
    The only information CICS TG has on the cause of the failure is
    theioexception details, so in this customer's case it will
    report the SSLHandshakeExceptionand the "no cipher suites in
    common" reason.
    

Local fix

  • N/A
    

Problem summary

  • When SSL Handshake is failed with I/O exception, the exception
    details are available only if trace is enabled.
    

Problem conclusion

  • CICS TG code is changed to log the information when SSL
    hangshake is failed with I/O Exception.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI87855

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8103

  • Reported release

    910

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-09-25

  • Closed date

    2017-10-31

  • Last modified date

    2017-10-31

  • APAR is sysrouted FROM one or more of the following:

    PI63870

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8103

Applicable component levels

  • R910 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]