IBM Support

PI85000: STORED PROCEDURE REPORT PERFORMANCE IS DEGRADED AFTER UPGRADE TOFIX PACK 8

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A report based on a stored procedure contains several items on
    the page based on the same stored procedure query.  In a
    previous version of 10.2.2, when the report was run the stored
    procedure would only be executed once.  After upgrading to Fix
    Pack 8, the stored procedure is run once for each object on the
    page, which makes the report take longer to complete.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM Cognos Business Intelligence 10.2.2 Fix Pack  *
    * 9                                                            *
    ****************************************************************
    Configuration Instructions:
    Requires the following setting in the <general> tab in
    xqe.config.xml file
    
          <queryReuse enabled="true" size="10">
               <allowReuseOfParameterizedQueries value="true"/>
           </queryReuse>
    

Problem conclusion

  • Code Fix
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI85000

  • Reported component name

    COG REPORT STUD

  • Reported component ID

    5724W12RS

  • Reported release

    A22

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-07-25

  • Closed date

    2017-09-19

  • Last modified date

    2017-09-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI85261 PI86244

Fix information

  • Fixed component name

    COG REPORT STUD

  • Fixed component ID

    5724W12RS

Applicable component levels

  • RA22 PSN

       UP