IBM Support

PI84837: IN FRENCH AND GERMAN REPORT VERSION SOME OF DECIMAL POINTS IN REPORT CHART SHOWING DOT AND NOT COMMA FOR DECIMAL SEPARATION MARK

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • When report data records are retrieved from Database decimal
    columns which have at least one "NULL" value then report output
    in French and German language version show decimal separation
    mark points in report chart as  . (dot) and not , (comma) as
    it is required for  French and German report language version.
    If there is no "NULL" in decimal column on database side decimal
    separation mark points show , (comma) as expected
    

Local fix

  • replace "NULL" with "0" (zero)
    on database side or to handle null on report side.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM Cognos Analytic 11.0.7.0                      *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI84837

  • Reported component name

    COG REPORT STUD

  • Reported component ID

    5724W12RS

  • Reported release

    A22

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-07-20

  • Closed date

    2017-08-15

  • Last modified date

    2017-08-15

  • APAR is sysrouted FROM one or more of the following:

    PI84147

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • RA22 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A22","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
15 August 2017