Fixes are available
APAR status
Closed as new function.
Error description
We have changed the security of the Gateway between v7.2 and v9.2 to ensure that no password is available in clear text on dumping the code. This caused the password field not to be set in the Gateway. The serverSecurity exits cannot see it in clear as it is not available in the gateway.
Local fix
NA
Problem summary
**************************************************************** * USERS AFFECTED: All users who use security exits * **************************************************************** * PROBLEM DESCRIPTION: The gateway security exit prior to * * V9.2 gave the password in clear text * * exit code, where it could be changed. * * V9.2 returned an encrypted password * * which could not be modified. This * * change of behavior caused the security * * exit code to fail. * * * **************************************************************** The gateway security exit prior to V9.2 gave the password in clear text to the exit code, where it could be changed. V9.2 returned an encrypted password which could not be modified. This change of behavior caused the security exit code to fail.
Problem conclusion
New function getPassword was implemented to get the password as clear text and setPassword was used to set it to a modified value.
Temporary fix
Comments
APAR Information
APAR number
PI83252
Reported component name
CICS TRNS GATE
Reported component ID
5724I8103
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-19
Closed date
2017-08-30
Last modified date
2017-08-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CICS TRNS GATE
Fixed component ID
5724I8103
Applicable component levels
R920 PSY
UP