Error description
When changing the port number of XD_AGENT port, the changes are not applied to the plugin-cfg.xml though they are applied in the configuration via the serverindex.xml. This is regarding the Intelligent Management stanza where the connector servers are listed.
Local fix
Update the plugin on the webserver with the correct port number.
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server WAS ND using the Intelligent * * Management for web servers feature. * **************************************************************** * PROBLEM DESCRIPTION: When XDAGENT_PORT values are changed * * the Intelligent Management for web * * servers generated plugin-cfg.xml is not * * updated. * **************************************************************** * RECOMMENDATION: * **************************************************************** When XDAGENT_PORT values are changed and Intelligent Management for web servers is enabled the plugin-cfg.xml is not updated to reflect the change.
Problem conclusion
The admin.intellmgmt component has been update to correct the issue and the updated observer behavior is as follows: 1) Change an XDAGENT_PORT value, save, and synchronize the change. 2) Bounce or start the process associated with XDAGENT_PORT change. At this point with the process actively using the newly defined XDAGENT_PORT all Intelligent Management enabled web server intellmgmt.xml files will be updated with correct connector values. 3) The plugin-cfg.xml file will then need to be regenerated for all Intelligent Management enabled web servers and propagated. NOTE: PI82240 has a prerequisite APAR of PI72201 and PI72201 has it's own prerequisite APAR of PI72200. All nodes in the environment need these APARs. The fix for this APAR is currently targeted for inclusion in fix packs 8.5.5.13 and 9.0.0.6. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
After changing XDAGENT_PORT values disable the Intelligent Management for web servers feature, re-enable the feature, and regenerate the plugin-cfg.xml.
Comments
APAR Information
APAR number
PI82240
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-26
Closed date
2017-11-01
Last modified date
2017-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R850 PSY
UP
Document Information
Modified date:
28 April 2022