Fixes are available
APAR status
Closed as program error.
Error description
User has service projects defined with the project feature of "Support IBM i objects" enabled so that they can access data areas and other objects on the IBM i when needed. It is found that each time a dataarea is accessed via DataAreaDefinition a new QZRCSRVS job is created. This results in many un-released QZRCSRVS jobs on the system.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of EGL Java accessing iSeries Data Objects via EGL * * Web Services * **************************************************************** * PROBLEM DESCRIPTION: * * iSeries connection job QZRCSRVS is not terminated after * * invoking an EGL Web Service that accesses iSeries data * * objects. Multiple invocations of this service will result in * * multiple instances of QZRCSRVS. These jobs are not released * * until the Web Server has terminated. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Testfix uploaded to fix portal. New function in ijavaLib.egl is added, called releaseConnection(). It must be invoked prior to the EGL Web Service terminating.
Temporary fix
Comments
APAR Information
APAR number
PI78240
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-15
Closed date
2017-11-10
Last modified date
2017-11-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
EGL Java
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R911 PSY
UP
R950 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
18 October 2021