IBM Support

PI77954: REMOVING A UCM STREAM WHILE A REMOTE REPLICA SITE HAS A VIEW OF THAT STREAM, CAUSES DATABASE PROBLEMS (REFORMATVOB, MKREPLICA)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • rmstream is blocked if the stream has view attached.
    However, if there is a new view that the stream master site does
    not know about because the remote site has not sync'd to the
    stream master since creating the view, then the rmstream is
    allowed to proceed.
       (Of course this is unavoidable.)
    
    Remote sites may have database problems affecting reformatvob
    and mkreplica, after they import the "rmstream" oplog entry.
    
    Examples:
    db_dumper: Error: Unexpected error from database library (8) in
    "/vobs/atria/lib/db/db__dump.c" line 3280
    db_dumper: Error: Error from libdb (8)
    cleartool: Error: Could not dump database.
    
    db_dumper: Error: Database identifier nnnnnn requested by client
    "" not found in VOB "/cag/drobinson/rms_pvob.vbs/db.reformat" in
    file "/vobs/atria/lib/db/db__obj.c" line 970.
    db_dumper: Error: Unexpected error from database library (1) in
    "/vobs/atria/lib/db/db__dump.c" line 6241
    db_dumper: Error: Error from libdb (1)
    cleartool: Error: Could not dump database.
    

Local fix

  • Contact ClearCase Technical Support for assistance to clean bad
    records out of the VOB database.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of ClearCase UCM.                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ClearCase rmstream is blocked if the stream has view         *
    * attached.  However, if there is a new view that the stream   *
    * master site does not know about because the remote site has  *
    * not sync'd to the stream master since creating the view,     *
    * then the rmstream is allowed to proceed.                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearCase versions 8.0.1.15, 9.0.0.5 and
    9.0.1.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI77954

  • Reported component name

    CC&CC MSITE WIN

  • Reported component ID

    5724G3300

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-03-10

  • Closed date

    2017-09-15

  • Last modified date

    2017-09-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CC&CC MSITE WIN

  • Fixed component ID

    5724G3300

Applicable component levels

  • R801 PSY

       UP

  • R900 PSY

       UP

  • R901 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSSH3S","label":"Rational ClearCase MultiSite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"900","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: