IBM Support

PI70915: COPY FULL NO WITH HARDCARDED DD CARDS FAILED WITH ABEND0C9 IN DSNUBASP.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • COPY FULL NO with hardcarded DD cards failed with abend0c9 in
    DSNUBASP.
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DB2 11 for z/OS users of COPY utility    *
    *                 with FULL NO or CHANGELIMIT options          *
    *                 against table spaces.                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: COPY utility with CHANGELIMIT or FULL   *
    *                      NO options and hardcoded DD cards       *
    *                      against a table space failed with       *
    *                      ABEND0C9 at DSNUBASP OFFSET00236 while  *
    *                      message DSNU404I was issued if the      *
    *                      output data set was defined by DD card. *
    ****************************************************************
    * RECOMMENDATION: Apply corrective PTF when available.         *
    ****************************************************************
    User ran an incremental COPY utility job (COPY FULL NO) on a
    table space and defined the output data set with a DD card.
    OPTIONS EVENT(ITEMERROR,SKIP) was specified.
    The COPY utility issued an error MSGDSNU404I - 'LOCAL SITE AND
    RECOVERY SITE INCREMENTAL IMAGE COPY ARE NOT SYNCHRONIZED FOR
    TABLESPACE tsname'. Although the object was marked skipped,
    COPY did not terminate with RC8 and instead continued to
    process the object after the DSNU404I error, resulting in the
    ABENDS0C9 at DSNUBASP + X'00236'.
    

Problem conclusion

  • Code has been changed in COPY utility against a table space
    to skip an error object after an empty output data set is
    allocated.
    This change does not affect COPY jobs which use TEMPLATEs for
    image copy output data sets.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI70915

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-10-19

  • Closed date

    2016-11-30

  • Last modified date

    2017-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI42988

Modules/Macros

  • DSNUBAII
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RB10 PSY UI42988

       UP16/12/15 P F612

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 January 2017