Fixes are available
APAR status
Closed as program error.
Error description
Random abends or too much data written to ELAWORK can happen in an IMSVS environment
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IMSVS users of cobolGen that have conversational programs * * that could have messages waiting on the IMS message queue. * **************************************************************** * PROBLEM DESCRIPTION: * * If the EGL cobolGen program does not exit, but instead has * * another message on the queue, certain program flags were not * * reset, nor was SSM memory released. This can cause the * * logical state of the program to be wrong and can lead to * * various abends or unwieldy growth of the ELAWORK database. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The software was updated to reset the flags and free the SSM storage when reading the next record from the IMS queue, as part of the processing for the previous IMS transaction.
Temporary fix
Comments
APAR Information
APAR number
PI69003
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-12
Closed date
2019-12-03
Last modified date
2019-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R901 PSY
UP
R911 PSY
UP
R950 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
18 October 2021