IBM Support

PI68883: WHEN ADMINPORT PARAMETER IS NOT SPECIFIED IN CTG.INI THE CTG WILL NOT START.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When adminport parameter is not specified in ctg.ini, message
    CTG6582E is displayed and CTG does not start.
    
    ..
    CTG6582E command line option -adminport= is unknown or needs a
    value. The default value is indicated on KC as '2810' is
    not taken.
    

Local fix

  • Specify a default Admin port
    

Problem summary

  • When the adminport is commented out or is not defined in the
    CICS TG initialization file then ctgd start fails with the
    message
    'CTG6582E The command line option -adminport= is unknown or
    requires a value'. That is because the ctgd startup script is
    trying to fetch the adminport from CICS TG initialization file
    and if it is not found, then it starts the Gateway daemon with
    null adminport which results in Gateway daemon failing to start
    and reported message is written.
    

Problem conclusion

  • CICS TG is changed to use the default adminport of 2810 when a
    value is not specified for adminport in the CICS TG
    initialization file.
    

Temporary fix

  • Specify a value for adminport.
    

Comments

APAR Information

  • APAR number

    PI68883

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8103

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-09-08

  • Closed date

    2017-06-12

  • Last modified date

    2017-06-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8103

Applicable component levels

  • R920 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
18 October 2021