PI68209: LARGE NUMBERS OF += MACRO REDEFINITIONS MAY CAUSE CLEARMAKE TO RUN OUT OF MEMORY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When performing a build using IBM Rational ClearCase's clearmake
    utility, a large number of successive "+=" redefinition of a
    make macro may cause clearmake to use all available process
    memory and abort.
    
    This issue requires approximately 9,000 lines in the form of:
    
    BIG_MACRO += A lot more text to add to BIG_MACRO
    
    to be present in the makefile.
    
    The same makefile will successfully process using the current
    GNU make.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of ClearCase clearmake with a large number of macros.  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ClearCase clearmake may run out of memory when a make file   *
    * contains a large number of macros.                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearCase version 9.0.1.4
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI68209

  • Reported component name

    CLEARCASE WIN

  • Reported component ID

    5724G2900

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-08-26

  • Closed date

    2018-08-10

  • Last modified date

    2018-08-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARCASE WIN

  • Fixed component ID

    5724G2900

Applicable component levels

  • R801 PSN

       UP

  • R900 PSN

       UP

  • R901 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"801","Line of Business":{"code":"LOB45","label":"Automation"}}]