A fix is available
APAR status
Closed as program error.
Error description
When using the work area sync operation to bring files from the filesystem into Synergy control, sync does not ignore files named .static_wa. This can result in a .static_wa file being created in and controlled by Rational Synergy. Controlling a file having this name can lead to a scenario in which the copy project operation will fail with the message "The work area path is not accessible".
Local fix
To prevent the sync operation from creating .static_wa files as controlled files, create a mapping rule to ignore files with this name. This can be done on a per-user basis by accessing Tools->Options->Actions Tab->Sync Work Area, or at the database level following the steps found here: http://www-01.ibm.com/support/docview.wss?uid=swg21568182.
Problem summary
**************************************************************** * USERS AFFECTED: * * GUI and CLI users * **************************************************************** * PROBLEM DESCRIPTION: * * WORK AREA SYNC OPERATION IN RATIONAL SYNERGY DOES NOT IGNORE * * .STATIC_WA FILE * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in Synergy 7.2.1.5 ifix002.
Temporary fix
Comments
APAR Information
APAR number
PI66585
Reported component name
TLOGIC SYNERGY
Reported component ID
5724V66SN
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-27
Closed date
2016-09-23
Last modified date
2016-09-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYNERGY
Fixed component ID
5724V66SN
Applicable component levels
R721 PSY
UP