IBM Support

PI66432: INVALID PART NUMBER ON A START DATABASE COMMAND RESULTS IN ABEND04E 00C90110 IN DSNTDCST AND DB2 CRASH DSNV086E 00E50706

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer issued invalid -START DATABASE command :
    
    -STA DB(CTASD000) SPACE(CTASS032) ACCESS(RW) PART(051:)
    
    and DB2 abended 04E RC00C90110 in DSNTDCST, with DB2 crash
    MSGDSNV086E RC00E50706
    
    Additional Symptoms : ABENDS0C4 00000004 DSNTDSTG OFFSET0326
                          ABEND04E RC00E20028 DSNSTACK OFFSET03AE
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: DB2 for z/OS Version 12 administrators,      *
    *                 executing either a DISPLAY, START, STOP or   *
    *                 ACCESS DATABASE command, specifying ranges  *
    *                 on the PART keyword.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: The syntax checking for ranges within   *
    *                      the PART keyword doesn't detect all     *
    *                      combinations of malformed range         *
    *                      specifications. Especially open         *
    *                      intervals (only the lower or upper end  *
    *                      of a range is specified but not both    *
    *                      ends) are not detected, leading to      *
    *                      unexpected behaviour when executing the *
    *                      command.                                *
    ****************************************************************
    * RECOMMENDATION: Specify the ranges of the PART keyword as    *
    *                 described in the DB2 documentation.          *
    ****************************************************************
    

Problem conclusion

  • The syntax verification is improved, detecting these kind of
    malformed range specifications for the PART keyword. These
    syntax errors now lead to a new DSNT325I message, indicating
    that the user has to correct the range specification.
    

Temporary fix

Comments

  • ×**** PE17/01/12 FIX IN ERROR. SEE APAR PI74845  FOR DESCRIPTION
    ×**** PE17/01/12 FIX IN ERROR. SEE APAR PI74845  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PI66432

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-25

  • Closed date

    2016-09-29

  • Last modified date

    2017-04-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI41281

Modules/Macros

  • DSN9SCNA DSNFCDIR DSNTDDIS DSNTDMSG DSNFTDIR
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RC10 PSY UI41281

       UP16/10/18 P F610

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
11 April 2017