IBM Support

PI65771: UNABLE TO INJECT PROGRAMMATICALLY ADDED FILTERS,SERVLETS AND LIS TENERS.

Fixes are available

9.0.0.1: WebSphere Application Server traditional V9.0 Fix Pack 1
9.0.0.2: WebSphere Application Server traditional V9.0 Fix Pack 2
9.0.0.3: WebSphere Application Server traditional V9.0 Fix Pack 3
9.0.0.4: WebSphere Application Server traditional V9.0 Fix Pack 4
9.0.0.5: WebSphere Application Server traditional V9.0 Fix Pack 5
9.0.0.6: WebSphere Application Server traditional V9.0 Fix Pack 6
9.0.0.7: WebSphere Application Server traditional V9.0 Fix Pack 7
9.0.0.8: WebSphere Application Server traditional V9.0 Fix Pack 8
9.0.0.9: WebSphere Application Server traditional V9.0 Fix Pack 9
9.0.0.10: WebSphere Application Server traditional V9.0 Fix Pack 10
9.0.0.11: WebSphere Application Server traditional V9.0 Fix Pack 11
9.0.5.0: WebSphere Application Server traditional Version 9.0.5 Refresh Pack
9.0.5.1: WebSphere Application Server traditional Version 9.0.5 Fix Pack 1
9.0.5.2: WebSphere Application Server traditional Version 9.0.5 Fix Pack 2
9.0.5.3: WebSphere Application Server traditional Version 9.0.5 Fix Pack 3
9.0.5.4: WebSphere Application Server traditional Version 9.0.5 Fix Pack 4
9.0.5.5: WebSphere Application Server traditional Version 9.0.5 Fix Pack 5
WebSphere Application Server traditional 9.0.5.6
9.0.5.7: WebSphere Application Server traditional Version 9.0.5 Fix Pack 7
9.0.5.8: WebSphere Application Server traditional Version 9.0.5.8
9.0.5.9: WebSphere Application Server traditional Version 9.0.5.9
9.0.5.10: WebSphere Application Server traditional Version 9.0.5.10
9.0.5.11: WebSphere Application Server traditional Version 9.0.5.11

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Injection fails for filters, servlets an listeners which are
    added programmatically, for example using a
    ServletContextListener.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Injection does not work for             *
    *                      programmatically added servlets,        *
    *                      filters and listeners.                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The WebContainer fails to look up injection targets for
    programmatically added servlets, filters and listeners and as a
    result injection is not performed.
    

Problem conclusion

  • The WebContainer code was modified to perform the required
    injection target look up for programmatically added servlets,
    filters and listeners.
    
    The fix for this APAR is currently targeted for inclusion in
    fix pack 9.0.0.1.  Please refer to the Recommended Updates
    page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI65771

  • Reported component name

    WEBSPHERE APP S

  • Reported component ID

    5724J0800

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-13

  • Closed date

    2016-08-23

  • Last modified date

    2016-08-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE APP S

  • Fixed component ID

    5724J0800

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
04 May 2022